Difference between revisions of "Preparing Cell Lysates"
From Bridges Lab Protocols
Davebridges (Talk | contribs) (edited table) |
Davebridges (Talk | contribs) m (→RIPA Buffer (for 10mL lysis buffer)) |
||
Line 11: | Line 11: | ||
|-NaF !! 1mM !! 20uL | |-NaF !! 1mM !! 20uL | ||
|-Protease Inhibitors !! 1 tab | |-Protease Inhibitors !! 1 tab | ||
+ | } | ||
==Basic Protocol== | ==Basic Protocol== |
Revision as of 21:15, 26 May 2009
Materials
RIPA Buffer (for 10mL lysis buffer)
{border = "1" cellspacing = "0" cellpadding = "5" |-Tris pH7.4 !! 50mM !! 500uL |-Na Deoxycholate !! 0.25% !! 250uL |-NP-40 !! 1% !! 1mL |-NaCl !! 150mM !! 375uL |-EDTA !! 1mM !! 20uL |-NaVO3 !! 1mM !! 100uL |-NaF !! 1mM !! 20uL |-Protease Inhibitors !! 1 tab }
Basic Protocol
- Stimulate cells if necessary
- Wash cells 2x1mL with ice cold PBS -/- and aspirate
- Add 200uL RIPA buffer and scrape cells
- Pipet into cold eppendorf tubes
- rotate end over end for 30 minutes at 4C to lyse
- Centrifuge 10 min at 13,000 RPM to clarify
- Transfer 150uL of lysate to fresh tube and add 150uL 2XSDS
- Load gel