Difference between revisions of "Glucose Tolerance Test"
From Bridges Lab Protocols
Davebridges (Talk | contribs) (→Materials (Bring Downstairs)) |
Davebridges (Talk | contribs) (→Protocol) |
||
Line 18: | Line 18: | ||
:#Pull up syringe and ensure that only air is aspirated. If urine or blood appears in the syringe, start over | :#Pull up syringe and ensure that only air is aspirated. If urine or blood appears in the syringe, start over | ||
:#Eject syringe. | :#Eject syringe. | ||
+ | #At desired intervals (normally 15, 30, 45, 60, 75, 90 and 120 min), take blood glucose measurements from tail vein |
Revision as of 15:42, 13 May 2009
Materials (Bring Downstairs)
- Glucometer
- Glucose Test Strips
- Scale
- Beaker for weighing mice
- Syringes
- 10% Glucose in PBS (make as 1g in 10 mL, sterile filtered). This will correspond to 1g/kg glucose injections.
Protocol
- Remove food from mice for about 6h. Add do not feed tag to cages.
- Bring mice to procedure room.
- Weigh mice, mark tails as necessary and take fasting glucose measurement.
- Prepare glucose syringes with 10 uL per g mouse weight (ie for a 30g mouse, 300 uL).
- At 1 min intervals, inject appropriate amount of glucose into interperitoneal cavity of the mouse.
- Immobilize mouse and restrain tail with one hand
- Aim needle between the midline and the hip bone
- Insert syringe (do not inject) into cavity
- Pull up syringe and ensure that only air is aspirated. If urine or blood appears in the syringe, start over
- Eject syringe.
- At desired intervals (normally 15, 30, 45, 60, 75, 90 and 120 min), take blood glucose measurements from tail vein