Insulin Tolerance Test

From Bridges Lab Protocols
Revision as of 13:45, 10 June 2009 by Davebrid (talk | contribs) (initial page)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Materials (Bring Downstairs

  • Glucometer - AccuChek Advantage
  • Glucose Test Strips - AccuChek Comfort Curve. Order these through Materiels Service by calling 936-6077 and ordering product 2535. For information see [here]
  • Scale
  • Beaker for weighing mice
  • Syringes
  • 0.07U/mL humulin in PBS (make as 70uL of 100 U/mL in 10 mL, sterile filtered). This will correspond to 0.7mU/kg injections.

Timer [edit]Protocol

  • Remove food from mice for about 6h. Add do not feed tag to cages, or move cage to procedure room.
  • Bring mice to procedure room. Put water bottle on cage.
  • Weigh mice, mark tails as necessary and take fasting glucose measurement.
  • Prepare glucose syringes with 10 uL per g mouse weight (ie for a 30g mouse, 300 uL).
  • At 1 min intervals, inject appropriate amount of glucose into interperitoneal cavity of the mouse.
  • Immobilize mouse and restrain tail with one hand
  • Aim needle between the midline and the hip bone
  • Insert syringe (do not inject) into cavity
  • Pull up syringe and ensure that only air is aspirated. If urine or blood appears in the syringe, start over
  • Eject syringe.
  • At desired intervals (normally 15, 30, 45, 60, 75, 90 and 120 min), take blood glucose measurements from tail vein
  • Analyse data by both % change from fasting glucose and absolute values