Difference between revisions of "Triglyceride Assay from Cells and Tissues"
From Bridges Lab Protocols
(→Protocol: Creation of Protocol) |
(→Protocol) |
||
Line 7: | Line 7: | ||
==Protocol== | ==Protocol== | ||
− | # | + | #Weigh out 30mg tissue (record weights for normalization) on dry ice into round bottom eppendorf tube. Add one stainless steel ball bearing. |
− | #Homogenize | + | #Add 500ul Homogenization Buffer |
− | # | + | #Homogenize with Qiagen Tissue Lyser for 3 minutes @ 25Hz for Liver/WAT or for 5 minutes @ 30Hz for muscle |
− | # | + | #Add 12.5ul KOH |
− | #Transfer | + | #Mix by inverting |
− | # | + | #Add 800ul '''Chloroform/Methanol Mixture''' |
− | #Add 50ul of sample | + | #Vortex vigorously then sit at room temperature for 5 minutes |
− | # | + | #Centrifuge for 10 minutes @ 13000G |
− | #Measure | + | #Transfer the bottom layer into a new tube |
+ | #Let evaporate overnight at room temperature | ||
+ | #If absorbance is going to be measured by cuvette, use non-bolded values. If using a plate reader, used bolded values. | ||
+ | #Add 500ul '''(50ul)''' of '''Butanol Mixture'''. See Suggested Volumes for your specific tissue. | ||
+ | #Measure triglyceride levels using SIgma Diagnostic Kit, using 5ul of sample. | ||
+ | ##Resuspend triglyceride and glycerol reagent with water if necessary | ||
+ | ##Calculate how many sample you have (samples + blank + standard curve) | ||
+ | ##Prepare reagent. You need 560ul '''(80ul)''' of glycerol reagent and 140ul '''(20ul)''' of triglyceride reagent. Make extra and combine in a Falcon tube. | ||
+ | ##Aliquot 700ul into a cuvette or '''100ul into a well of a 96 well plate''' | ||
+ | ##For standars, add 0-5ul of glycerol standard | ||
+ | ##Add 5ul of resuspended lipid to each well to start (also make a 5ul blank of the butanol mixture) and mix. | ||
+ | ##Let sit for ~30 mins @ room temperature (or 5mins @ 37C if you are in a hurry). If using >10ul of butanol mix the solution may be cloudy. Let it settle and it should become more clear. | ||
+ | ##Measure absorbance @ 540nm | ||
+ | ##If any samples are A540<0.1 or above the 5ul standard the A540, then repeat with more or less lipid as required. |
Revision as of 21:26, 31 July 2013
Materials
- Homogenization Buffer (50 mM Tris pH 8, 5 mM EDTA, 30 mM Mannitol, PI inhibitor, can be made in bulk without the PI, PI added fresh)
- 10M KOH
- Chloroform/Methanol Mixture (2:1)
- Butanol Mixture: 3 mL butanol, 1.66 mL Triton-X114, 0.33 mL Methanol
- Sigma Triglyceride Assay Kit (Cat TR0100)
Protocol
- Weigh out 30mg tissue (record weights for normalization) on dry ice into round bottom eppendorf tube. Add one stainless steel ball bearing.
- Add 500ul Homogenization Buffer
- Homogenize with Qiagen Tissue Lyser for 3 minutes @ 25Hz for Liver/WAT or for 5 minutes @ 30Hz for muscle
- Add 12.5ul KOH
- Mix by inverting
- Add 800ul Chloroform/Methanol Mixture
- Vortex vigorously then sit at room temperature for 5 minutes
- Centrifuge for 10 minutes @ 13000G
- Transfer the bottom layer into a new tube
- Let evaporate overnight at room temperature
- If absorbance is going to be measured by cuvette, use non-bolded values. If using a plate reader, used bolded values.
- Add 500ul (50ul) of Butanol Mixture. See Suggested Volumes for your specific tissue.
- Measure triglyceride levels using SIgma Diagnostic Kit, using 5ul of sample.
- Resuspend triglyceride and glycerol reagent with water if necessary
- Calculate how many sample you have (samples + blank + standard curve)
- Prepare reagent. You need 560ul (80ul) of glycerol reagent and 140ul (20ul) of triglyceride reagent. Make extra and combine in a Falcon tube.
- Aliquot 700ul into a cuvette or 100ul into a well of a 96 well plate
- For standars, add 0-5ul of glycerol standard
- Add 5ul of resuspended lipid to each well to start (also make a 5ul blank of the butanol mixture) and mix.
- Let sit for ~30 mins @ room temperature (or 5mins @ 37C if you are in a hurry). If using >10ul of butanol mix the solution may be cloudy. Let it settle and it should become more clear.
- Measure absorbance @ 540nm
- If any samples are A540<0.1 or above the 5ul standard the A540, then repeat with more or less lipid as required.